from Ed Harris, KE4SKY, Virginia RACES Training Officer on August 11, 2001
View comments about this article!


Virginia ARES / RACES

0x01 graphic

Lead-Acid Battery Fact Sheet:

Typical 12-volt lead-acid batteries have a voltage of about 14 volts when fully charged and 11 volts fully discharged. Most amateur radio equipment doesn't operate properly below 11.5 volts. You cannot practically exceed the depth of discharge at which battery voltage under load drops to below that figure. Over-sized loads or excessive duty cycle causes rapid depletion of battery capacity, so battery systems must be sized for the expected load.

Cranking amps tell nothing about how long a starting battery can run your transmitter. Cold Cranking Amps (CCA) represent the current a ">start-ing" battery provides continuously for 30 seconds at zero degs. F before voltage is drops to 1.7 volts per cell at which point it is fully discharged. MCA or Marine Cranking Amps are measured at 32 degs. F. Reserve capacity is the time a starting battery can sustain a 25-amp load before cell voltage drops to 1.7vpc. A 12-volt battery has six cells, so at 1.7 vpc, a discharged battery has only 10.2 volts. Most 12-volt radio equipment fails to function properly before a lead-acid battery is fully discharged. Discard any 12-volt battery with open-circuit voltage below 10.2 volts, it probably has a bad cell and probably won't accept a full recharge.

Performance measurements for "deep cycle" batteries are amp-hour capacity at a specified depth of discharge (DoD). Amp-hour capacity is current available over time, measured at 80 degs. F. DoD is percentage of capacity available during a charge-discharge cycle. Amp-hour ratings of deep cycle batteries are based upon a discharge rate at 1/20 capacity, expressed as C over 20". A marine battery rated 200ah at C20, when discharged continuously at 10 amps, at 80o F., sustains the load for 20 hrs. Starting batteries are designed for 20% DoD, gel cells 25%, "deep cycle" batter-ies from 50% to 80%.

Engine starting batteries perform poorly for communications because they are designed for short periods of high load. Deep cycle batteries are better for communications because they withstand long periods of slow discharge.

For a typical 25% transmit duty cycle, a 100w HF rig on SSB, requires 20 amps on transmit, provided by a minimum BCI Group 27 Marine deep cycle battery (65 pounds!) to stay within a C20 discharge rate, at 80oF. A smaller group U1, 33ah gel cell (25 lbs.) will power the same HF rig at reduced power, such as 25w, with a loss of about an S-unit in signal strength. At lower temperatures, available capacity is reduced. Lead-acids lose 50% of their capacity at 32oF!

More rapid rates of discharge (such as using a margin-ally sized battery for the load) reduce capacity and the number of charge-discharge cycles the battery will provide. A BCI Group U1 (25 lb., 31ah) gel cell, often recommended for portable communications, is well balanced to power a 2-meter mobile at 20-25% duty cycle, on medium power (10-25w) transmit, requiring about 6A, approximating the C20 discharge rate. Increasing transmitter output to 50w increases the current load to 10 amps, approximating C/10 at the same duty cycle. The battery will tolerate intermittent full power 50w transmit, but routine use of an undersized battery for such duty severely shortens its useful life.

A common rule for sizing communications battery systems for a C/20 discharge rate is one amp-hour per watt of transmitter output. Estimate the amp-hour capacity required for 24 hours by summing all loads: transmit current times total operating time times duty cycle, plus receive current with squelch open times standby time and repeat for each piece of equipment. Multiply total loads by 150% safety factor and assume the result as a minimum for 24 hours of SSB or 12 hours of FM or digital operations. For greater confidence of adequate capacity in critical systems, use a factor of 200%.

Measuring Sg of a wet, lead-acid battery during dis-charge is a good indicator of the state of charge. A fully charged battery has an Sg of 1.265 grams per cc, at 75% charge 1.225, 50% charge 1.19, fully discharged 1.120.

Because of uncertainty of mixing, Sg is not an abso-lute measure of capacity, but should always be considered in combination with load testing and open circuit voltage. This is because during charging of a flooded battery Sg lags charge state because complete mixing of the elec-trolyte does not occur until gassing commences at the end of the charge cycle.

Lead-acids at normal ambient temperature should be recharged with current of 1/10 to 1/20 of capacity. They will accept only about 1/10 of the charging cur-rent at 30 degs. F which they will at 80 degs. F.

When not in service all lead-acid batteries self-discharge at rate of about 5% per month. Rate of self-discharge increases with temperature. If left in a deeply discharged condition for a long time lead-acid batteries"sulfate" as sulfur in the acid combines with lead in the plates to form lead sulfate.

Auxiliary batteries should be connected to a charge con-troller to provide a regulated, low-level current of 1 to 1.5% of C to com-pensate for self-discharge and protect against sulfating.

A fully-automatic, low amperage charger such as the Schumacher Model SE-1-12S, available from Sears or Wal-Mart for around $25, recharges small SLA batteries and will maintain vehicle starting or deep cycle batteries up to BSI Group 30 (105ah).

Flooded lead-acid batteries require regular testing, inspection and replace-ment of lost electrolyte. If water is lost during charging and not replaced, the process of sulfating is accelerated in plates, which are partially exposed, to air. "Treeing" is a short circuit occurring between positive and negative plates. This may be caused by manufacturing defects or rough han-dling, which results in misalignment of the plates and separators. "Mossing" caused by circulating electrolyte bringing partic-ulate matter to the tops of the plates can also cause a short.

Sealed, flooded (wet) lead-acid batteries also called "maintenance free" and experience less self-dis-charge. They contain lead-calcium or lead-strontium plates to re-duce water loss and usually have catalytic recombiners to reduce water loss and sealed, valve regulated vents. Sealed-flooded lead-acids tolerate the same temperatures as unsealed batteries, but because Sg isn't r-eadily measured, some sealed-wet batteries are provided with a captive float hydrometer in the electrolyte.

Sealed-wet batteries are common for engine starting, but s-hould not be discharged below 25%, or their life is dramatically short-ened.

Sealed lead-acid (SLA) batteries include gel cells and absorbed glass mat (AGM) types. Sometimes called "starved" electrolyte or valve- regulated, these units are completely sealed. Be-cause there is no free liquid electrolyte to spill, the battery can be used safely in any position. SLAs are safer than flooded types for indoor use and in sensitive equip--ment such as computer backup power supplies, which would be damaged by exposure to acid fumes.

Any sealed battery will vent if overcharged to the point of excessive gassing, because the valves are designed to purge excessive pressure building up inside the battery case. Therefore, battery chargers designed for flooded cells must not be used to charge gel cells unless they have voltage limiting circuitry to prevent exceeding 14V during charging.

Self-discharge of gel cells is mini-mized by storing them in moderately cool areas of 5 to 15 degs. C. A suitable charger for larger gel cell batteries is the Schumacher SE-600A especially for 12-volt gel cell batteries, see http://www.batterychargers.com

Auxiliary batteries in your ham shack may also be floated in parallel across a regulated 13.8V DC power supply. Shotky diodes should be placed in line to prevent back-feed into the power supply if the AC mains fail and the system "fails to battery."

Most gel cells are NOT deep cycle. Depth of discharge greater than 25% significantly reduces their life. Gel cells must not be used below -20 degs.C; in vehicle engine compartments or in uses subjecting them to temperatures above 50 degs. C.

Absorbed glass mat (AGM) batteries are deep cycle can be quickly recharged with no current limit and provides a broad operating temperature range. Their depth of discharge approaches wet NiCds, with reduced maintenance and lower life cycle cost. New aviation AGMs are more expensive than flooded deep cycle batteries of equal capacity, but much less expensive than flooded NiCds.

Marine or emergency vehicle AGMs such as Lifeline or Optima are not prohibitively expensive, have aviation type cell construction and are very well suited as auxiliary power sources for emergency communications.

For more information go to the reference library at http://www.aresva.org *

2

Member Comments:
This article has expired. No more comments may be added.
 
Sealed Lead-Acid Battery Fact Sheet  
by N6AJR on August 11, 2001 Mail this to a friend!
Excellent article, thanks. One question, I have a single large (800cca+) marine starting/deep cycle battery. I was planning to use a charge controller from a solar photovoltaic system and use a 20 amp power supply as the source of power to kep the battery charged, in parallel with the source and the radio. Is there a better way to do this.

I would usually only be charging the battery when operating the radio, a couple hours at a time. I will also use this battery to drive a 500 watt linear ( draws around 80 amps). Later I plan to add several more identical or near identical batteries to this setup for long term emergency power for the ham gear( I live in California)and eventually run a solar panel or three and a wind turbine if I gan get it past the building inspector in my town. Any ideas on direction? thanks tom N6AJR
 
Sealed Lead-Acid Battery Fact Sheet  
by K8DXX on August 12, 2001 Mail this to a friend!
Great article.

What can you tells us about the 17 amp hour batteries that are sold for emergency jump starts? Any helpful hints? I'd like to run my IC 746 off one, on SSB and probably 50 watts PEP.

73

Bill / K8DXX
 
RE: Sealed Lead-Acid Battery Fact Sheet  
by KA4P on August 12, 2001 Mail this to a friend!
Thanks for the info. I saved this one to my hard drive for future reference.
 
Sealed Lead-Acid Battery Fact Sheet  
by K3AN on August 12, 2001 Mail this to a friend!
Nice article. Here are some additional comments.

I have powered my home station (100W HF Xcvr, VHF FM/packet) with a 10 Amp homebrew regulated charger and a 100 AH, size 27 deep cycle battery. I got tired of using a 20 Amp power supply that would "fold back" when the 20 Amp limit was temporarily exceeded. This would typically happen with the CW key down and the TNC/VHF radio sending an ACK packet. The voltage drop would cause the TNC to reset, losing my packet connection. Now the station can draw 30 A. or more on peaks, as long as the average draw doesn't exceed 10 Amps. And with the HF power throttled back, I can operate for at least several hours (many hours of VHF-only operation) without depending on the AC mains.

The charger uses an LM-317 regulator circuit, with "wrap-around" PNP power transistors to boost the current rating. I can leave this charger connected to the battery all the time, even when the charger is unplugged from the AC (which it is when I'm not operating). The leakage path through the voltage-setting resistors is just 6 milliamps (4.3 Amp-hours per month), which is about the same as the self-discharge loss of the battery itself. I do disconnect the charger if I expect a period of inactivity greater than a week or two. The charger has a switch to set a float level of 13.8 Volts or an equalize voltage of 14.4 Volts. Potentiometers allow fine adjustment of the settings.

The first battery lasted almost 10 years. It just lost capacity at the end, even though the no-load/no charge voltage was still around 12.6. I probably should have replaced it a year earlier.

One important thing. You MUST fuse all connections to the positive terminal of the battery, AND ALSO protect against contact with the positive terminal and unfused portion of the positive bus. It's not the voltage you're worried about, it's the current. Short circuit currents can exceed 200 Amps, which can melt insulation and start fires. The case could concieveably rupture as the acid comes to a boil (and pressure builds up) in a prolonged short condition. Since the battery will usually be on the floor, you don't want the possibility of a dropped tool, or anything metallic, being able to make contact with both the positive and negative battery terminals.

To really have some reserve capacity, I think my next battery will be two 6 Volt golf cart batteries wired in series. These are now available from places like Sears, and provide twice the capacity while avoiding the problems of parallel batteries, where the stronger one discharges into the weaker one whenever they're not under charge.
 
Sealed Lead-Acid Battery Fact Sheet  
by KF0K on August 12, 2001 Mail this to a friend!
Nice article.....I want to run a 6M amp (375W @ +/- 55 amps)....I think a deep cycle marine battery would work for this. Can some of you experienced tinkerers help me out with the best way to go about this? E-mail me at kf0k@cs.com if you would please. Maybe a 70A PS (56A cont.) would be a better idea??
 
Sealed Lead-Acid Battery Fact Sheet  
by KF4VRB on August 12, 2001 Mail this to a friend!
I posted this on another group about a month ago, but since someone wanted to know about the jump starter battery deals, I thought I'd share it here also...

After seeing a couple of those battery powered jump start booster cable things on sale, I figured I'd see if they could be of some use to me. After skipping the battery booster info, I looked into the specs. An 18 Amp hour 12 VDC battery with onboard charger, DC outlet , 8 AWG jumper style cables with heavy duty clamps, onboard power meters/diagnostic lights, and it came in one heavy duty carrying case. I have been meaning to upgrade my sole 4 amp hour dc power source/air compressor combo to something with a little more kick, and nothing but pure power (I mean the compressor is nice, but for mountain topping???) So I proceeded to pick up 2 of those jokers and took them home to charge them up. Next I picked up a 5watt and 15watt solar panel to charge my batteries when I should be so unfortunate to not have commercial power. I already had a 5watt that is slightly fragile, but works great when you are careful. The 5w solar cells will be used for charging the batteries when I just need a radio to use while camping, utilizing the 45 watt 2meter/70cm booster just for emergencys and ocassional ragchews. I could also use this to power a crossband repeat rig at the base, effectively improving the range of the handhelds in my group. If I planned on using it a little more often, then I would use both the battery packs along with the 15w solar panel. This last setup I plan on using with an HF rig to go mountain topping later this year. I also plan on making a power distribution buss for this too.
Sometimes things that have been eating away at you suddenly become clear after investing in new equipment. I have been wanting to utilze the crossband repeat Kenwood TH-79 with docking booster rig in my vehicle while doing whatever I need to. Problems: One, I didn't want to leave my rig visible in my vehicle. Two, the DC outlet is not powered when key is not in ignition (I know easy fix, but I just do not want to do it that bad!). Three, I didn't want to run a (fused on both - & + leads)wire from the trunk to the car battery for an outlet, just call me lazy ! Four, it would be for rare occassions and not worth the effort. And Finally Five, I didn't want an extended ragchew to leave me stranded with a dead battery. So now with these power stations I can pop one in a Secure trunk, hook up my rig to power station, reroute my coax, and hook up a small 5 watt solar panel and leave it in the back window to trickle charge the powerstation while stationary. While driving a wire plugged in the vehicles DC power, charges up the Power Stations battery. One last note about this is that the Radio in the trunk and Power Station must be secured inside, so in case you gotta bug out, your equipment will not be busted when you get done! Portable, temporary, convienent, that is what I like!


Also they worked really good doing the jump start also...
 
Sealed Lead-Acid Battery Fact Sheet  
by W8PT on August 13, 2001 Mail this to a friend!
Very Good Article, but what is "Sg" [10th section in text]??
 
Battery Information Links  
by KE4SKY on August 13, 2001 Mail this to a friend!
The domain name for Virginia ARES / RACES Inc. has changed. Please use http://www.va-ares.org to access the reference library and training links.

73 de KE4SKY
Virginia State RACES Training Officer
 
RE: Sealed Lead-Acid Battery Fact Sheet  
by KE6MIY on August 13, 2001 Mail this to a friend!
"SG" stands for "specific gravity". It is a ratio of the density of one fluid to another "standard" fluid (usually water). In this case a cubic centimeter(cc) of battery acid is 1.xxx times denser than a cc of pure water. Hope this helps. Dave
 
RE: Sealed Lead-Acid Battery Fact Sheet  
by KE4SKY on August 13, 2001 Mail this to a friend!
Sg is an appreviation for Specific Gravy of the electrolyte, given as grams per cubic centimeter.
 
RE: Sealed Lead-Acid Battery Fact Sheet  
by KE4SKY on August 13, 2001 Mail this to a friend!
For a large amp which requires something in the neighborhood of 50 ampheres in current, to stay within a C/20 discharge rate would require a battery bank approximating 1000 amp-hours, such as a group of eight L-16 golf cart batteries in series-parallel connections to provide 12V. For intermittent, occasional use you could get away with a smaller bank approximating 500ah, such as four L-16s.
 
RE: Sealed Lead-Acid Battery Fact Sheet  
by KE4SKY on August 13, 2001 Mail this to a friend!
For charging and maintaining large battery banks use of solar panels approximating 5% of the system capacity with a charge controller is recommended. For simply maintaining the battery back against self-discharge while the station is idle, a smaller set of panels of 1% to 1-1/2% of system capacity is adequate. Some sources state that small solar systems of less than 1-1/2% of system capacity are effectively self-regulating and do not require charge regulation. However, the voltage of many solar panels is around 18V, so use of a charge controller is necessary for gel cell and AGM batteries to reduce gassing which may cause bubbles in the gel or separation of the glass matting between the plates, which reduces capacity. Use of a charge controller will also reduce gassing which causes evaporation of water from the eletrolyte in flooded battery systems, reducing maintenance requirements.

If floating your batteries across a regulated 13.8V power supply you can probably do so without a charge controller, as long as you have both power leads to your equipment fused at the battery and blocking diodes in line to protect your power supply if the AC mains go down and the system fails to battery.
 
Sealed Lead-Acid Battery Fact Sheet  
by NB6Z on August 13, 2001 Mail this to a friend!
"...and 11 volts fully discharged." This is true IF the discharge is C/20. 11 volts measured on a 12V lead acid battery under a heavy load doesn't meen it is fully or nearly discharged... It could meen you have the wrong capacity battery for the application.
 
Sealed Lead-Acid Battery Fact Sheet  
by N8LXR on August 13, 2001 Mail this to a friend!
Simple question: On the consumer market, what is the largest marine deep cycle battery avaliable in amp hours? Or perhaps one of the larger ones? I am told by a fellow ham that there is a military type battery that has 800 amp hours of reserve capacity, but have yet to find it.

Tim
N8LXR
morsenut@aol.com
 
Sealed Lead-Acid Battery Fact Sheet  
by N8LXR on August 13, 2001 Mail this to a friend!
An article on QST states that if a lead acid battery is kept at above 50% charge, its voltage with stay above 12V. Can you confirm this?


Tim
N8LXR
 
RE: Sealed Lead-Acid Battery Fact Sheet  
by NB3O on August 13, 2001 Mail this to a friend!
Sg stands for specific gravity relative to distilled water.
 
RE: Sealed Lead-Acid Battery Fact Sheet  
by KE4SKY on August 14, 2001 Mail this to a friend!
Lead-acid batteries are available in some HUGE sizes for stationary use in marine, solar power, telephone switching and other industrial applications.

Quite frankly, the average amateur radio operator has NO business fooling with batteries that are so large that you can't lift them by yourself! The common Group 27 or Group 30 marine batteries are entirely adequate for most auxiliary power situations. If you need to build a large battery bank, then a group of L-16 golf cart batteries can be managed one at a time by a trained and careful individual.

I would be very cautious before considering placement of multiple larger batteries, each containing 5 gallons or more of acid anywhere near my home QTH. If you are trained and capable of handling such large battery banks and you can meet all of the OSHA, and NEC requirements for managing them, you shouldn't have to ask anyone here how to do it.






 
RE: Sealed Lead-Acid Battery Fact Sheet  
by KE4SKY on August 14, 2001 Mail this to a friend!
If a six-cell, lead-acid nominal 12V is maintained above 50% charge, its no-load, open circuit voltage will be above 12 volts, sure! That's a given.

However, depending upon the construction of the battery and its rated depth of discharge, it still may not provide sufficient current to power your rig.

Gel cell batteries are typically rated for only about 25 percent depth of discharge, similar to engine starting batteries. Most Absorbed Glass Matt or AGM types are deep cycle and can handle 50 percent depth of discharge, but if you go to the battery performance curves at any of the manufacturer's web sites or the Battery Council International, you will see that discharging most lead-acid batteries below 50% really reduces the number of charge-discharge cycles that they can provide.
 
RE: Sealed Lead-Acid Battery Fact Sheet  
by KE4SKY on August 14, 2001 Mail this to a friend!
The 17ah batteries used for portable jump starts will run your HF rig at 50 watts SSB for a a few hours if your duty cycle is modest, for occasional DX and casual rag chewing. But an increased duty cycle such as heavy contest use, running data modes or FM will draw it down very MUCH faster.

For ARES / RACES use we like the 17ah batteries because they are a great size for portable backpack operation. But to ensure useful operating time andacceptable battery life cycle, limit the discharge rate of the battery to C/20, by limiting transmitter output to 1 watt per amp-hour.
 
RE: Sealed Lead-Acid Battery Fact Sheet  
by N2MR on August 14, 2001 Mail this to a friend!
Good reading
http://www.redbeardyachtsystems.com/Marine%20Battery%20Facts.htm

Mark
 
Sealed Lead-Acid Battery Fact Sheet  
by WB3FUM on August 14, 2001 Mail this to a friend!
Good article Ed. Hope to see you sometime soon possibly at one of the Virginia ARES RACES, Inc. Training sessions.
 
Sealed Lead-Acid Indoors?  
by K2MIT on August 16, 2001 Mail this to a friend!
I remember material from my technician and general exam about batteries generating potentially combustable hydrogen. Was that for an older technology.

In other words, can I get one of these deep cycle batteries and a charger and stuff it in my small room basement hamshack without worrying about blowing up the place?

Great article.

--Jeffrey Steinberg, K2MIT
 
RE: Sealed Lead-Acid Indoors?  
by KE4SKY on August 17, 2001 Mail this to a friend!
Sealed lead-acid batteries such as gel cell and AGM are valve regulated and will remain sealed unless overcharged to the point that gas builds up pressure inside the case to "vent" them.

SLA and AGM are intended for safe use in sensitive environments such as hospitals, aircraft, and telecommunications where delicate equipment would be damaged by acid fumes or where explosive atmospheres must be avoided. Gel and AGM batteries use calcium-lead alloy which reduce gassing and the better brands also use catalytic caps which help to faciliate recombination of liberated oxygen and hydrogen from charging back into water to reduce gassing and loss of electrolyte.

Gell cell or AGM are the battery construction of choice for most telecommunications, solar power, computer UPS and home amateur station battery backup. If you use conventional flooded batteries they must be boxed, stored upright and well ventilated!

SLA and AGM batteries need to be charged at a slow and controlled rate to reduce internal gassing which causes bubbling in the gel or pockets in the glass matting which reduce contact of the plates with the captive electrolyte, which reduces capacity. Chargers intended for SLA and AGM batteries should not exceed 2.33 volts per cell, or 14 volts for a minimal 12 volt battery and the rate of charge should not exceed C/20 in order to minimize gassing. Most common automative and marine battery chargers intended for flooded batteries approach 16V and will swell up a gell cell battery until it looks like the Pillsbury DoughBoy!

The small 1.5 amp automatic battery "maintainers" such as by Schumacher at www.batterychargers.com compare the battery voltage against a programmed reset point in the CPU, starting to charge when battery voltage drops below 12.8V and cutting off when it reaches 13.8V. The Guest Battery Pal and Schumacher maintainers also have reverse polarity, overvoltage and thermal protection and do a good job at maintaining AGM and gel cells up to a Group 27. They area great buy at around $30. I have one on each vehicle, several in the shack, one in my jump kit and another at maintain the "house" battery at the hunting cabin. These do a great job for charging small gell cells from 2-50 ah and also recharge a larger battery such as a Group 27, though when you run down one from a contest weekend or Field Day it may take several days to get the job done on a battery larger than 30ah.

 